Broadsoft – SIPRec Recording – Failover & Redndancy

This document contains information related to the support of Redundancy and Failover for CallCabinets Broadsoft Call Recording Solutions.

Prerequisites:

  1. Two or more servers that are running CallCabinet’s BroadSoft call recording software.
  2. Access to a domain and associated ability to make SRV DNS changes, for more info in SRV records click here

Installation Steps:

  1. Assign an DNS domain name to each of the existing servers example: server1.callcabinet.com and server2.callcabinet.com
  2. Create SVR records for each server:
  3. _service._proto.name. TTL class SRV priority weight port target
    _sip._tcp.example.com. 86400 IN SRV 10 100 15060 server1.callcabinet.com.
    _sip._tcp.example.com. 86400 IN SRV 10 0 15060 server2.callcabinet.com.

  4. Adjust the weight values for each server, the values must add up to a total of 100, In the example above the server in entry 1 (server1.callcabinet.com), will always be used as the primary recording server and will only failover to server 2 in the event that the server is non-responsive. Where the following example would allow load balancing and failover in a 60/40 ratio

    _service._proto.name. TTL class SRV priority weight port target
    _sip._tcp.example.com. 86400 IN SRV 10 60 15060 server1.callcabinet.com.
    _sip._tcp.example.com. 86400 IN SRV 10 40 15060 server2.callcabinet.com.


    There is no limit to the number of servers to add to the redundancy or failover group.
    NOTE: Please make sure to point the Broadworks SIPREC recording service to the DNS name and not a static IP.